Weight : about 1.3kg Size: 170mm×90mm×63mm

12V20A Lifepo4 Battery Charger Spec 5
12V20Ah lithium battery Charge Curve

 Protect Characteristics

  • Output Over-Voltage Protection
  • Output Over Current Protection
  • Short Circuit Protection
  • Over-Temperature protection

Electronic Characteristics

No. Item Unit Min. Typ. Max. Remark
1Input voltage Vac 200220260 
2Input power – – 391.2 
3Constant charge
voltage 
Vdc 14.314.614.9 
4Float voltage(for
lead acid battery
only)
Vdc – –  
5Constant charge
current 
192021 
6Charge complete
current 
1.41.61.8 
7Ripple voltage – – – Constant charge
voltage*1%
 
8Efficiency 80– – Full load

Protect Characteristics

Output Over Voltage Protection
When the charger output voltage exceeds the maximum charging voltage, the charger enters the standby state protection. It will restore to normal working condition automatically after troubleshooting.

Output Over Current Protection
When the charger output current exceeds the maximum charging current, the charger enters the over-current protection status. It will restore to normal working conditions automatically after troubleshooting.

Short Circuit Protection
When the charger has a short circuit at the output, the charger enters short-circuit protection status. It will restore to normal working conditions automatically after troubleshooting.

Over-Temperature protection
When the charger’s internal temperature exceeds 85, it will be Into the over-temperature protection state and the cuts off output, and the cooling fan stop working. When the temperature returns to 65, the charge is restored again

Insulation Characteristics

Insulation resistantInput to output DC500V 50MΩmin (25℃, Humidity≤70%)
Input to case DC500V 50MΩmin (25℃, Humidity≤70%)
Output to case DC500V 50MΩmin (25℃, Humidity≤70%)
Hi-PotInput to output 1500Vac 50Hz 1minute ≤10mA
Input to case 1500Vac 50Hz 1minute ≤10mA
Output to case 500Vac 50Hz 1minute ≤10mA

Reliability

No. Item Description Remark
1MTBF average operating life ≥ 30000h 25℃
2Anti-vibration 5mm/50Hz/600s vibration test PASS

Standard specifies

EN 55022:2006+A1:2007
EN 61000-3-2:2006+A1:2009+A2::2009
EN 61000-3-3:2008
EN 55024:1998+A1:2001+A2:2003

Electromagnetic Interference

Conducted interference: EN55011.13.14-1.15.22.FCC part 1518.VCCI;
Radiated interference: EN55011.13.22.FCCpart 15
18.VCCI/EN55013.EN55014-1.

Working Conditions & Storage Conditions

Working Conditions
Ambient temperature: -5℃ ~ +40;
RH: 5%
95%;
Max. altitude: 2000 meter;
Cooling: UY series chargers use of forced air cooling system. Under dustless and ventilated
conditions, the full load temperature rise not exceeding 40
℃.
Storage Conditions
Ambient temperature: -40℃ ~ +70;
RH: 0%
95%;
Max. altitude: 20000 meter.